    • Proprietary pH sensor technology and materials from Switzerland
    • Unique LabSen HF glass membrane, which has a faster response rate, better repeatability in strong acid samples, and resistant to hydrofluoric corrosion
    • Silver Ion Trap Reference System - On top of the Long-Life reference system, a silver ion trap is added to prevent the junction being blocked by silver sulfide
    • Standard BNC Connector
    • 6-Month Warranty fulfilled by Apera Instruments

    Backed by proprietary Swiss sensor technology and materials, the LabSen 831 HF pH Electrode Probe is designed for pH measurements for solutions containing Hydrofluoric acid (≥3pH), or other strong acid solutions.

    Special Glass Membrane - Unique LabSen HF glass membrane, which has a faster response rate, better repeatability in strong acid samples, and resistant to hydrofluoric corrosion.

    Silver Ion Trap Reference System - The LabSen 831 pH electrode adopts a Silver Ion Trap reference system. On top of the Long-Life reference system, a silver ion trap is added to prevent the junction being blocked by silver sulfide.

    The electrode uses a BNC connector, compatible with any pH meters that use BNC connectors, such as Apera Instruments MP511, SX811, PH700, PH800, PC800, PH820 and PC820. The temperature sensor is not built-in. Users need to have a separate temperature probe (ex: Apera Instruments MP500) to enable ATC or manually input temperature to realize temperature compensation.

    The electrode is backed up with a 6-month warranty by Apera Instruments.

  • Description
  • Specs
  • Documents
  • Parts
  • Reviews
  • Warranty
    • Proprietary pH sensor technology and materials from Switzerland
    • Unique LabSen HF glass membrane, which has a faster response rate, better repeatability in strong acid samples, and resistant to hydrofluoric corrosion
    • Silver Ion Trap Reference System - On top of the Long-Life reference system, a silver ion trap is added to prevent the junction being blocked by silver sulfide
    • Standard BNC Connector
    • 6-Month Warranty fulfilled by Apera Instruments

    Backed by proprietary Swiss sensor technology and materials, the LabSen 831 HF pH Electrode Probe is designed for pH measurements for solutions containing Hydrofluoric acid (≥3pH), or other strong acid solutions.

    Special Glass Membrane - Unique LabSen HF glass membrane, which has a faster response rate, better repeatability in strong acid samples, and resistant to hydrofluoric corrosion.

    Silver Ion Trap Reference System - The LabSen 831 pH electrode adopts a Silver Ion Trap reference system. On top of the Long-Life reference system, a silver ion trap is added to prevent the junction being blocked by silver sulfide.

    The electrode uses a BNC connector, compatible with any pH meters that use BNC connectors, such as Apera Instruments MP511, SX811, PH700, PH800, PC800, PH820 and PC820. The temperature sensor is not built-in. Users need to have a separate temperature probe (ex: Apera Instruments MP500) to enable ATC or manually input temperature to realize temperature compensation.

    The electrode is backed up with a 6-month warranty by Apera Instruments.

    Material: Lead-free glass

    Temp. Sensor: No

    Junction: Ceramic

    Reference: Silver Ion Trap

    Electrolyte: 3M KCL

    Length: 120mm

    Diameter: 12mm

    Membrane Shape: Half-Ball

    Range: 0-11 pH

    Temp. Range: 0 to 100°C (32 to 212°F)

    Connector: BNC

    Cable: 3 Ft

    Material: Lead-free glass

    Temp. Sensor: No

    Junction: Ceramic

    Reference: Silver Ion Trap

    Electrolyte: 3M KCL

    Length: 120mm

    Diameter: 12mm

    Membrane Shape: Half-Ball

    Range: 0-11 pH

    Temp. Range: 0 to 100°C (32 to 212°F)

    Connector: BNC

    Cable: 3 Ft

Compare Products