Fast multi-point Auto Calibration — Simple calibration workflow with on-screen guidance and self diagnosis, automatically recognizing pH calibration buffers 1.68, 4.00, 7.00, 10.01, 12.45 and conductivity calibration solutions 1413 µS/cm, 12.88 mS/cm, 84 µS/cm, 1118.mS/cm.
Electrode Health Monitoring — Real-time slope display between pH calibrations helps you quickly assess the condition and performance of your pH electrode.
GLP-Ready Data Management — Stores up to 1000 data sets with timestamps. USB data output supports smooth transfer to PC-link for audits, reporting, and further analysis.
Cross-Platform PC-Link Software (Windows & Mac) — No installation required—just plug in and retrieve all stored measurements at once. Offers real-time charting, immediate visual feedback, and one-click export to CSV or professional PDF reports (including measurements, calibration date, pH electrode slope, offset, meter model and serial number).
201T-F All-in-One pH/Temp Electrode — Built with Apera’s proprietary lithium-glass membrane for high stability and accuracy. The dual ceramic–fiber junction minimizes clogging, while the integrated temperature sensor enables true automatic temperature compensation (ATC). Detachable sensor shield protects the sensitive glass bulb.
2301T-F ATC Conductivity Electrode — Featured with a proprietary firm platinum-black cell (K=1.0) for exceptional stability and ±1% F.S. accuracy across a wide range (0 to 200 mS/cm)
Universal BNC Electrode Compatibility — Standard BNC connector works seamlessly with Apera’s LabSen® pH electrodes, supporting a wide range of specialty pH applications.
What's in the Kit
| Item | Quantity |
|---|---|
| PC800 Benchtop pH Meter | 1 |
| 201T-F pH/Temperature Electrode | 1 |
| 2301T-F Conductivity/Temperature Electrode | 1 |
| pH 4.00 Calibration Buffer | 1 |
| pH 7.00 Calibration Buffer | 1 |
| pH 10.01 Calibration Buffer | 1 |
| 84 µS/cm Conductivity Calibration Solution | 1 |
| 1413 µS/cm Conductivity Calibration Solution | 1 |
| 12.88 mS/cm Conductivity Calibration Solution | 1 |
| 602 Flexible Electrode Holder | 1 |
| USB Cable | 1 |
| Flashdrive for PC-link Software | 1 |
| 9V Power Adapter | 1 |
| User Manual | 1 |
| Quick Start Guide | 1 |
|
Parameter |
Model |
PC800 |
|
pH |
Electrode |
201T-F 3-in-1 Combination pH Electrode |
|
Measuring Range |
(-2 to 19.99) pH |
|
|
Resolution |
0.1/0.01 pH |
|
|
Accuracy |
±0.01 pH ±1 digit |
|
|
Input Current |
≤1x10-12A |
|
|
Input Impedance |
≥1x1012 Ω |
|
|
Stability |
±0.01 pH/3h ±1 digit |
|
|
Temp. Compensation Range |
0 to 100°C (32 to 212°F) auto or manual |
|
|
mV |
Measuring Range |
±1999 mV |
|
Resolution |
1 mV |
|
|
Accuracy |
±0.1% F.S ±1 digit |
|
|
Conductivity |
Electrode |
2301T-F Combination Conductivity Electrode |
|
Measuring Range |
Conductivity: |
|
|
TDS: (0 to 100) g/L |
||
|
Salinity: (0 to 100) ppt |
||
|
Resistivity: (0 to 100) MΩ?cm |
||
|
Resolution |
0.01/0.1/1μS/cm |
|
|
Accuracy |
±1.0% F.S. |
|
|
Temp. Compensation Range |
0 to 50°C (32 to 122°F) auto or manual |
|
|
Electrode Constant |
0.01/0.1/1/10 cm-1 |
|
|
Temp. |
Measuring Range |
0 to 100°C (32 to 212°F) |
|
Resolution |
0.1°C |
|
|
Accuracy |
±0.5°C ±1 digit |
|
|
Others |
Data Storage |
1000 sets |
|
Storage Content |
Numberings, Date, Time, |
|
|
Data Output |
USB |
|
|
Power Supply |
Input: 120V AC 60Hz; Output: DC9V/300mA, 2.7VA |
|
|
IP Rating |
IP54 Splash-proof and dust-proof |
|
|
Dimensions and Weight |
(9*9.5*6) inches / pounds; with case: 10*10*7 / 7 pounds approx |
We warrant this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of THREE YEARS for the instrument and SIX MONTHS for the probe from the delivery.
This limited warranty does NOT cover any issues due to:
Fast multi-point Auto Calibration — Simple calibration workflow with on-screen guidance and self diagnosis, automatically recognizing pH calibration buffers 1.68, 4.00, 7.00, 10.01, 12.45 and conductivity calibration solutions 1413 µS/cm, 12.88 mS/cm, 84 µS/cm, 1118.mS/cm.
Electrode Health Monitoring — Real-time slope display between pH calibrations helps you quickly assess the condition and performance of your pH electrode.
GLP-Ready Data Management — Stores up to 1000 data sets with timestamps. USB data output supports smooth transfer to PC-link for audits, reporting, and further analysis.
Cross-Platform PC-Link Software (Windows & Mac) — No installation required—just plug in and retrieve all stored measurements at once. Offers real-time charting, immediate visual feedback, and one-click export to CSV or professional PDF reports (including measurements, calibration date, pH electrode slope, offset, meter model and serial number).
201T-F All-in-One pH/Temp Electrode — Built with Apera’s proprietary lithium-glass membrane for high stability and accuracy. The dual ceramic–fiber junction minimizes clogging, while the integrated temperature sensor enables true automatic temperature compensation (ATC). Detachable sensor shield protects the sensitive glass bulb.
2301T-F ATC Conductivity Electrode — Featured with a proprietary firm platinum-black cell (K=1.0) for exceptional stability and ±1% F.S. accuracy across a wide range (0 to 200 mS/cm)
Universal BNC Electrode Compatibility — Standard BNC connector works seamlessly with Apera’s LabSen® pH electrodes, supporting a wide range of specialty pH applications.
What's in the Kit
| Item | Quantity |
|---|---|
| PC800 Benchtop pH Meter | 1 |
| 201T-F pH/Temperature Electrode | 1 |
| 2301T-F Conductivity/Temperature Electrode | 1 |
| pH 4.00 Calibration Buffer | 1 |
| pH 7.00 Calibration Buffer | 1 |
| pH 10.01 Calibration Buffer | 1 |
| 84 µS/cm Conductivity Calibration Solution | 1 |
| 1413 µS/cm Conductivity Calibration Solution | 1 |
| 12.88 mS/cm Conductivity Calibration Solution | 1 |
| 602 Flexible Electrode Holder | 1 |
| USB Cable | 1 |
| Flashdrive for PC-link Software | 1 |
| 9V Power Adapter | 1 |
| User Manual | 1 |
| Quick Start Guide | 1 |
|
Parameter |
Model |
PC800 |
|
pH |
Electrode |
201T-F 3-in-1 Combination pH Electrode |
|
Measuring Range |
(-2 to 19.99) pH |
|
|
Resolution |
0.1/0.01 pH |
|
|
Accuracy |
±0.01 pH ±1 digit |
|
|
Input Current |
≤1x10-12A |
|
|
Input Impedance |
≥1x1012 Ω |
|
|
Stability |
±0.01 pH/3h ±1 digit |
|
|
Temp. Compensation Range |
0 to 100°C (32 to 212°F) auto or manual |
|
|
mV |
Measuring Range |
±1999 mV |
|
Resolution |
1 mV |
|
|
Accuracy |
±0.1% F.S ±1 digit |
|
|
Conductivity |
Electrode |
2301T-F Combination Conductivity Electrode |
|
Measuring Range |
Conductivity: |
|
|
TDS: (0 to 100) g/L |
||
|
Salinity: (0 to 100) ppt |
||
|
Resistivity: (0 to 100) MΩ?cm |
||
|
Resolution |
0.01/0.1/1μS/cm |
|
|
Accuracy |
±1.0% F.S. |
|
|
Temp. Compensation Range |
0 to 50°C (32 to 122°F) auto or manual |
|
|
Electrode Constant |
0.01/0.1/1/10 cm-1 |
|
|
Temp. |
Measuring Range |
0 to 100°C (32 to 212°F) |
|
Resolution |
0.1°C |
|
|
Accuracy |
±0.5°C ±1 digit |
|
|
Others |
Data Storage |
1000 sets |
|
Storage Content |
Numberings, Date, Time, |
|
|
Data Output |
USB |
|
|
Power Supply |
Input: 120V AC 60Hz; Output: DC9V/300mA, 2.7VA |
|
|
IP Rating |
IP54 Splash-proof and dust-proof |
|
|
Dimensions and Weight |
(9*9.5*6) inches / pounds; with case: 10*10*7 / 7 pounds approx |
|
Parameter |
Model |
PC800 |
|
pH |
Electrode |
201T-F 3-in-1 Combination pH Electrode |
|
Measuring Range |
(-2 to 19.99) pH |
|
|
Resolution |
0.1/0.01 pH |
|
|
Accuracy |
±0.01 pH ±1 digit |
|
|
Input Current |
≤1x10-12A |
|
|
Input Impedance |
≥1x1012 Ω |
|
|
Stability |
±0.01 pH/3h ±1 digit |
|
|
Temp. Compensation Range |
0 to 100°C (32 to 212°F) auto or manual |
|
|
mV |
Measuring Range |
±1999 mV |
|
Resolution |
1 mV |
|
|
Accuracy |
±0.1% F.S ±1 digit |
|
|
Conductivity |
Electrode |
2301T-F Combination Conductivity Electrode |
|
Measuring Range |
Conductivity: |
|
|
TDS: (0 to 100) g/L |
||
|
Salinity: (0 to 100) ppt |
||
|
Resistivity: (0 to 100) MΩ?cm |
||
|
Resolution |
0.01/0.1/1μS/cm |
|
|
Accuracy |
±1.0% F.S. |
|
|
Temp. Compensation Range |
0 to 50°C (32 to 122°F) auto or manual |
|
|
Electrode Constant |
0.01/0.1/1/10 cm-1 |
|
|
Temp. |
Measuring Range |
0 to 100°C (32 to 212°F) |
|
Resolution |
0.1°C |
|
|
Accuracy |
±0.5°C ±1 digit |
|
|
Others |
Data Storage |
1000 sets |
|
Storage Content |
Numberings, Date, Time, |
|
|
Data Output |
USB |
|
|
Power Supply |
Input: 120V AC 60Hz; Output: DC9V/300mA, 2.7VA |
|
|
IP Rating |
IP54 Splash-proof and dust-proof |
|
|
Dimensions and Weight |
(9*9.5*6) inches / pounds; with case: 10*10*7 / 7 pounds approx |
|
Parameter |
Model |
PC800 |
|
pH |
Electrode |
201T-F 3-in-1 Combination pH Electrode |
|
Measuring Range |
(-2 to 19.99) pH |
|
|
Resolution |
0.1/0.01 pH |
|
|
Accuracy |
±0.01 pH ±1 digit |
|
|
Input Current |
≤1x10-12A |
|
|
Input Impedance |
≥1x1012 Ω |
|
|
Stability |
±0.01 pH/3h ±1 digit |
|
|
Temp. Compensation Range |
0 to 100°C (32 to 212°F) auto or manual |
|
|
mV |
Measuring Range |
±1999 mV |
|
Resolution |
1 mV |
|
|
Accuracy |
±0.1% F.S ±1 digit |
|
|
Conductivity |
Electrode |
2301T-F Combination Conductivity Electrode |
|
Measuring Range |
Conductivity: |
|
|
TDS: (0 to 100) g/L |
||
|
Salinity: (0 to 100) ppt |
||
|
Resistivity: (0 to 100) MΩ?cm |
||
|
Resolution |
0.01/0.1/1μS/cm |
|
|
Accuracy |
±1.0% F.S. |
|
|
Temp. Compensation Range |
0 to 50°C (32 to 122°F) auto or manual |
|
|
Electrode Constant |
0.01/0.1/1/10 cm-1 |
|
|
Temp. |
Measuring Range |
0 to 100°C (32 to 212°F) |
|
Resolution |
0.1°C |
|
|
Accuracy |
±0.5°C ±1 digit |
|
|
Others |
Data Storage |
1000 sets |
|
Storage Content |
Numberings, Date, Time, |
|
|
Data Output |
USB |
|
|
Power Supply |
Input: 120V AC 60Hz; Output: DC9V/300mA, 2.7VA |
|
|
IP Rating |
IP54 Splash-proof and dust-proof |
|
|
Dimensions and Weight |
(9*9.5*6) inches / pounds; with case: 10*10*7 / 7 pounds approx |
Compatibility
We warrant this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of THREE YEARS for the instrument and SIX MONTHS for the probe from the delivery.
This limited warranty does NOT cover any issues due to: