PC910 Benchtop pH/Conductivity Meter Kit
- Description
- Specs
- Videos
- Citations
- Parts
- Documents
- Warranty
Instrument Features
-
Advanced, Intuitive Interface — Plain-language menus and graphic screen prompts eliminate the need for extensive manual reading or training. Multi-language support includes English, German, Spanish, and Chinese.
-
Dual-Channel Simultaneous Measurement — Measures pH/mV(ORP) and conductivity/TDS/salinity at the same time for maximum efficiency.
-
GLP Data Management — Manual/automatic data logger with 200 sets of GLP-compliant data storage containing calibration data and time stamps. Export data via USB to PC.
Web PC-Link Software — allows you to connect your to a PC or Mac to capture, organize, analyze, and export measurements and calibration records in LIMS-ready CSV or JSON formats.
pH/mV (ORP) Measurement
- LabSen® 211 pH Electrode — Features a low-impedance glass membrane and long-life reference system. Supports 0–100°C ATC via the MP500 temperature probe. Compatible with TRIS buffers.
-
Flexible Calibration Options — 1 to 3 point auto. calibration recognizing standard buffers (1.68 / 4.00 / 7.00 / 10.01 / 12.45) or user-defined standards. Automatic electrode slope display and calibration self-diagnosis.
-
Broad Compatibility — Standard BNC pH connector & RCA temperature connector (NTC 30KΩ). Compatible with all Swiss LabSen electrodes for specialized samples.
Conductivity/TDS/Salinity/Resistivity Measurement
-
2301T-F Conductivity Electrode — firm platinum black sensor delivers high-accuracy measurements from 0 to 200 mS/cm at ±1% F.S accuracy.
-
Flexible Conductivity Calibration — 1 to 4 point auto. calibration with standard solutions (84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm) or user-defined standards.
-
Quick Parameter Switching — One-tap conversion among conductivity, TDS, and salinity.
-
Multiple Salinity Modes — Select from general salinity, saltwater salinity, or NaCl salinity.
-
Broad Compatibility — Standard BNC conductivity connector; compatible with 2310T-F (up to 2000 mS/cm) and DJS-0.1-F for high-purity water. Uses RCA temperature connector (NTC 30KΩ).
Parameter Settings Menu
Parameter Menu Options Factory Default 1.0 pH 1.1 pH Buffer Selection CH / USA / NIST / User USA 1.2 Resolution 0.01 / 0.1 0.01 1.3 Last Calibration Data View — 1.4 Restore Factory Default Yes / No No 2.0 Conductivity / TDS 2.1 Cell Constant 10 / 1.0 / 0.1 1.0 2.2 CAL Solution Selection Standard / CN / User Standard 2.3 Last Calibration Data View — 2.4 Reference Temperature 15–30 °C 25 °C 2.5 Temp Compensation Factor 0.00–10.00% 2.0% 2.6 TDS Factor 0.40–1.00 0.71 2.7 Restore Factory Default Yes / No No 3.0 Configuration 3.1 Reading with HOLD On / Off — 3.2 Auto Timing Data Log Manual / Automatically Manual 3.3 Temperature Unit °C / °F — 3.4 Delete Saved Data Yes / No No 3.5 Language Selection English / Deutsch / Español / Chinese — 3.6 Date Format Y-M-D — 3.7 Time Format 24-hour / 12-hour — 3.8 Date Setting YYYY-MM-DD — 3.9 Time Setting HH:MM:SS — What's in the Kit?
Item Quantity PC910 pH/Conductivity Meter 1 602 Flexible Electrode Holder 1 LabSen 211 Glass pH Combination Electrode 1 MP500 Temperature Electrode 1 2301T-F Conductivity Electrode (ATC, K=1.0) 1 pH Standard Buffers (4.00 / 7.00 / 10.01 pH, 50mL each) 3 Conductivity Calibration Solutions (84 µS / 1413 µS / 12.88 mS, 50mL each) 3 USB Cable 1 PC-Link 9500 Flash Drive 1 9V Adapter 1 User Manual 1 -
Parameter Specification pH Measurement Measuring Range 0.00 – 14.00 pH Resolution 0.1 / 0.01 pH Accuracy ±0.01 pH ±1 digit Temp. Compensation Range 32 – 212°F (0 – 100°C), Auto or Manual Calibration Points 1–3 points mV Measurement Measuring Range ±2000 mV Resolution 1 mV Accuracy ±0.1% F.S. ±1 digit Conductivity / TDS / Salinity Conductivity Measuring Range 0 – 200 mS/cm (auto range):
(0 – 19.99) µS/cm
(20.0 – 199.9) µS/cm
(200 – 1999) µS/cm
(2.00 – 19.99) mS/cm
(20.0 – 199.9) mS/cmTDS Measuring Range 0 – 100 g/L Salinity Measuring Range 0 – 100 ppt Resolution 0.01 / 0.1 / 1 µS/cm; 0.01 / 0.1 mS/cm Accuracy ±1.0% F.S. ±1 digit Temp. Compensation Range 32 – 122°F (0 – 50°C), Auto or Manual Cell Constant 0.1 / 1 / 10 cm⁻¹ Temperature Measurement Measuring Range 32 – 212°F (0 – 100°C) Resolution 0.1°F (0.1°C) Accuracy ±0.9°F (±0.5°C) ±1 digit Other Technical Parameters Data Storage 200 sets Storage Contents Numberings, date, time, measurement value, temperature Power Supply DC 9V / 600 mA Dimensions & Weight 195 × 215 × 100 mm / 0.9 kg - Citations
We warrant this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of THREE YEARS for the instrument and SIX MONTHS for the probe from the delivery.
This limited warranty does NOT cover any issues due to:
- Accidental damage
- Improper use
- Normal wear and tear
- Transportation
- Storage
- Failure to follow the product instructions
- Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
- Unauthorized repair
- External causes such as accidents, abuse, or other actions or events beyond our reasonable control.
- Description
- Specs
- Videos
- Citations
- Documents
- Parts
- Warranty
Instrument Features
-
Advanced, Intuitive Interface — Plain-language menus and graphic screen prompts eliminate the need for extensive manual reading or training. Multi-language support includes English, German, Spanish, and Chinese.
-
Dual-Channel Simultaneous Measurement — Measures pH/mV(ORP) and conductivity/TDS/salinity at the same time for maximum efficiency.
-
GLP Data Management — Manual/automatic data logger with 200 sets of GLP-compliant data storage containing calibration data and time stamps. Export data via USB to PC.
Web PC-Link Software — allows you to connect your to a PC or Mac to capture, organize, analyze, and export measurements and calibration records in LIMS-ready CSV or JSON formats.
pH/mV (ORP) Measurement
- LabSen® 211 pH Electrode — Features a low-impedance glass membrane and long-life reference system. Supports 0–100°C ATC via the MP500 temperature probe. Compatible with TRIS buffers.
-
Flexible Calibration Options — 1 to 3 point auto. calibration recognizing standard buffers (1.68 / 4.00 / 7.00 / 10.01 / 12.45) or user-defined standards. Automatic electrode slope display and calibration self-diagnosis.
-
Broad Compatibility — Standard BNC pH connector & RCA temperature connector (NTC 30KΩ). Compatible with all Swiss LabSen electrodes for specialized samples.
Conductivity/TDS/Salinity/Resistivity Measurement
-
2301T-F Conductivity Electrode — firm platinum black sensor delivers high-accuracy measurements from 0 to 200 mS/cm at ±1% F.S accuracy.
-
Flexible Conductivity Calibration — 1 to 4 point auto. calibration with standard solutions (84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm) or user-defined standards.
-
Quick Parameter Switching — One-tap conversion among conductivity, TDS, and salinity.
-
Multiple Salinity Modes — Select from general salinity, saltwater salinity, or NaCl salinity.
-
Broad Compatibility — Standard BNC conductivity connector; compatible with 2310T-F (up to 2000 mS/cm) and DJS-0.1-F for high-purity water. Uses RCA temperature connector (NTC 30KΩ).
Parameter Settings Menu
Parameter Menu Options Factory Default 1.0 pH 1.1 pH Buffer Selection CH / USA / NIST / User USA 1.2 Resolution 0.01 / 0.1 0.01 1.3 Last Calibration Data View — 1.4 Restore Factory Default Yes / No No 2.0 Conductivity / TDS 2.1 Cell Constant 10 / 1.0 / 0.1 1.0 2.2 CAL Solution Selection Standard / CN / User Standard 2.3 Last Calibration Data View — 2.4 Reference Temperature 15–30 °C 25 °C 2.5 Temp Compensation Factor 0.00–10.00% 2.0% 2.6 TDS Factor 0.40–1.00 0.71 2.7 Restore Factory Default Yes / No No 3.0 Configuration 3.1 Reading with HOLD On / Off — 3.2 Auto Timing Data Log Manual / Automatically Manual 3.3 Temperature Unit °C / °F — 3.4 Delete Saved Data Yes / No No 3.5 Language Selection English / Deutsch / Español / Chinese — 3.6 Date Format Y-M-D — 3.7 Time Format 24-hour / 12-hour — 3.8 Date Setting YYYY-MM-DD — 3.9 Time Setting HH:MM:SS — What's in the Kit?
Item Quantity PC910 pH/Conductivity Meter 1 602 Flexible Electrode Holder 1 LabSen 211 Glass pH Combination Electrode 1 MP500 Temperature Electrode 1 2301T-F Conductivity Electrode (ATC, K=1.0) 1 pH Standard Buffers (4.00 / 7.00 / 10.01 pH, 50mL each) 3 Conductivity Calibration Solutions (84 µS / 1413 µS / 12.88 mS, 50mL each) 3 USB Cable 1 PC-Link 9500 Flash Drive 1 9V Adapter 1 User Manual 1 Parameter Specification pH Measurement Measuring Range 0.00 – 14.00 pH Resolution 0.1 / 0.01 pH Accuracy ±0.01 pH ±1 digit Temp. Compensation Range 32 – 212°F (0 – 100°C), Auto or Manual Calibration Points 1–3 points mV Measurement Measuring Range ±2000 mV Resolution 1 mV Accuracy ±0.1% F.S. ±1 digit Conductivity / TDS / Salinity Conductivity Measuring Range 0 – 200 mS/cm (auto range):
(0 – 19.99) µS/cm
(20.0 – 199.9) µS/cm
(200 – 1999) µS/cm
(2.00 – 19.99) mS/cm
(20.0 – 199.9) mS/cmTDS Measuring Range 0 – 100 g/L Salinity Measuring Range 0 – 100 ppt Resolution 0.01 / 0.1 / 1 µS/cm; 0.01 / 0.1 mS/cm Accuracy ±1.0% F.S. ±1 digit Temp. Compensation Range 32 – 122°F (0 – 50°C), Auto or Manual Cell Constant 0.1 / 1 / 10 cm⁻¹ Temperature Measurement Measuring Range 32 – 212°F (0 – 100°C) Resolution 0.1°F (0.1°C) Accuracy ±0.9°F (±0.5°C) ±1 digit Other Technical Parameters Data Storage 200 sets Storage Contents Numberings, date, time, measurement value, temperature Power Supply DC 9V / 600 mA Dimensions & Weight 195 × 215 × 100 mm / 0.9 kg Parameter Specification pH Measurement Measuring Range 0.00 – 14.00 pH Resolution 0.1 / 0.01 pH Accuracy ±0.01 pH ±1 digit Temp. Compensation Range 32 – 212°F (0 – 100°C), Auto or Manual Calibration Points 1–3 points mV Measurement Measuring Range ±2000 mV Resolution 1 mV Accuracy ±0.1% F.S. ±1 digit Conductivity / TDS / Salinity Conductivity Measuring Range 0 – 200 mS/cm (auto range):
(0 – 19.99) µS/cm
(20.0 – 199.9) µS/cm
(200 – 1999) µS/cm
(2.00 – 19.99) mS/cm
(20.0 – 199.9) mS/cmTDS Measuring Range 0 – 100 g/L Salinity Measuring Range 0 – 100 ppt Resolution 0.01 / 0.1 / 1 µS/cm; 0.01 / 0.1 mS/cm Accuracy ±1.0% F.S. ±1 digit Temp. Compensation Range 32 – 122°F (0 – 50°C), Auto or Manual Cell Constant 0.1 / 1 / 10 cm⁻¹ Temperature Measurement Measuring Range 32 – 212°F (0 – 100°C) Resolution 0.1°F (0.1°C) Accuracy ±0.9°F (±0.5°C) ±1 digit Other Technical Parameters Data Storage 200 sets Storage Contents Numberings, date, time, measurement value, temperature Power Supply DC 9V / 600 mA Dimensions & Weight 195 × 215 × 100 mm / 0.9 kg -
Parameter Specification pH Measurement Measuring Range 0.00 – 14.00 pH Resolution 0.1 / 0.01 pH Accuracy ±0.01 pH ±1 digit Temp. Compensation Range 32 – 212°F (0 – 100°C), Auto or Manual Calibration Points 1–3 points mV Measurement Measuring Range ±2000 mV Resolution 1 mV Accuracy ±0.1% F.S. ±1 digit Conductivity / TDS / Salinity Conductivity Measuring Range 0 – 200 mS/cm (auto range):
(0 – 19.99) µS/cm
(20.0 – 199.9) µS/cm
(200 – 1999) µS/cm
(2.00 – 19.99) mS/cm
(20.0 – 199.9) mS/cmTDS Measuring Range 0 – 100 g/L Salinity Measuring Range 0 – 100 ppt Resolution 0.01 / 0.1 / 1 µS/cm; 0.01 / 0.1 mS/cm Accuracy ±1.0% F.S. ±1 digit Temp. Compensation Range 32 – 122°F (0 – 50°C), Auto or Manual Cell Constant 0.1 / 1 / 10 cm⁻¹ Temperature Measurement Measuring Range 32 – 212°F (0 – 100°C) Resolution 0.1°F (0.1°C) Accuracy ±0.9°F (±0.5°C) ±1 digit Other Technical Parameters Data Storage 200 sets Storage Contents Numberings, date, time, measurement value, temperature Power Supply DC 9V / 600 mA Dimensions & Weight 195 × 215 × 100 mm / 0.9 kg Compatibility
We warrant this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of THREE YEARS for the instrument and SIX MONTHS for the probe from the delivery.
This limited warranty does NOT cover any issues due to:
- Accidental damage
- Improper use
- Normal wear and tear
- Transportation
- Storage
- Failure to follow the product instructions
- Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
- Unauthorized repair
- External causes such as accidents, abuse, or other actions or events beyond our reasonable control.