    • Advanced, Intuitive Interface — Plain-language menus and graphic screen prompts eliminate the need for extensive manual reading or training. Multi-language support includes English, German, Spanish, and Chinese.

    • Dual-Channel Simultaneous Measurement — Measures pH/mV(ORP) and conductivity/TDS/salinity/resistivity at the same time for maximum efficiency.

    • Powerful Data Management —Manual/automatic data logger with 2000 sets of GLP-compliant data storage, including electrode ID, user ID, sample ID, company name, and optional calibration password protection.

      Export data via USB to PC or a mini-printer (sold separately).

    • i-Guide On-Screen Tutorials — Press the “i” key at any time for step-by-step setup and calibration instructions displayed directly on the screen.

    • Apera TestBench Included — Integrated workstation with a flexible electrode holder, intelligent magnetic stirrer, and buffer organizers — dramatically streamlines calibration and measurement workflows.

    pH/mV (ORP) Measurement

    • LabSen® 211 pH Electrode — Features a low-impedance glass membrane and long-life reference system for ±0.003 pH accuracy. Supports 0–100°C ATC via the MP500 temperature probe. Compatible with TRIS buffers.
    • Flexible Calibration Options — 1 to 5 point auto. calibration recognizing standard buffers (1.68 / 4.00 / 7.00 / 10.01 / 12.45) or user-defined standards. Automatic electrode slope display and calibration self-diagnosis.

    • Broad Compatibility — Standard BNC pH connector & RCA temperature connector (NTC 30KΩ). Compatible with all Swiss LabSen electrodes for specialized samples.

    Conductivity/TDS/Salinity/Resistivity Measurement

    • 2401T-F Conductivity Electrode (Included) — Glass-body delivers high-accuracy measurements from 0 to 200 mS/cm at ±0.5% F.S accuracy.

    • Flexible Conductivity Calibration — 1 to 4 point auto. calibration with standard solutions (84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm) or user-defined standards.

    • Quick Parameter Switching — One-tap conversion among conductivity, TDS, salinity, and resistivity.

    • Multiple Salinity Modes — Select from general salinity, saltwater salinity, or NaCl salinity.

    • Broad Compatibility — Standard BNC conductivity connector; compatible with 2310T-F (up to 2000 mS/cm) and DJS-0.1-F for high-purity water. Uses RCA temperature connector (NTC 30KΩ).

    Parameter Settings Menu

    Menu Parameter Options Default
    pH pH Buffer Standard USA / NIST / User USA
    Resolution 0.001 / 0.01 / 0.1 0.01
    Calibration Info View / Print View
    Calibration Reminder Off / Hour / Day Off
    Stability Standard Low / Medium / High Medium
    Max/Min Reading Alarm Off / Max / Min Off
    Display Mode Digital / Dial Digital
    Electrode ID Custom Input ---
    Back to Factory Default No / Yes No
    Conductivity / TDS / Salinity Cell Constant 10 / 1.0 / 0.1 1.0
    Calibration Standard Standard / CH / User Standard
    Calibration Info Check / Print Check
    Calibration Reminder Off / Hour / Day Off
    Reference Temp. 15–30°C 25°C
    Temp. Compensation Coefficient 0.00–10.00% 2.00%
    TDS Factor 0.40–1.00 0.71
    Salinity Type Linear / NaCl / Saltwater (Seawater) Linear
    Electrode ID Custom Input ---
    Back to Factory Default No / Yes No
    Data Management Logging Destination Memory / Printer / PC Memory
    Logging Mode Manual / Auto Manual
    Printing Format Simple / Complete Simple
    Delete Data Yes / No No
    General Settings Sample ID Custom Input ---
    User ID Custom Input ---
    Company Name Custom Input ---
    Calibration Password Custom Input None
    Display Info Simple / Complete Simple
    Auto Hold On / Off Off
    Temperature Unit °C / °F °C
    Date Format YYYY-MM-DD / MM-DD-YYYY / DD-MM-YYYY YYYY-MM-DD
    Language English / German / Spanish / French / Italian / Chinese / Japanese English

    What's in the Kit?

    Item Quantity
    PC9500 pH/Conductivity Meter 1
    606 Test-Bench (with flexible electrode holder) 1
    LabSen 211 Glass pH Combination Electrode 1
    MP500 Temperature Electrode 1
    2401T-F Conductivity Electrode (ATC, K=1.0) 1
    pH Standard Buffers (4.00 / 7.00 / 10.01 pH, 50mL each) 3
    Conductivity Calibration Solutions (84 µS / 1413 µS / 12.88 mS, 50mL each) 3
    Stirrer Power Cable 1
    USB Cable 1
    PC-Link 9500 Flash Drive 1
    9V Adapter 1
    Calibration Vials 6
    L200 Stir Beads 6
    User Manual 1
  • Description
  • Specs
  • Videos
  • Citations
  • Documents
  • Parts
  • Warranty
  • Instrument Features

    • Advanced, Intuitive Interface — Plain-language menus and graphic screen prompts eliminate the need for extensive manual reading or training. Multi-language support includes English, German, Spanish, and Chinese.

    • Dual-Channel Simultaneous Measurement — Measures pH/mV(ORP) and conductivity/TDS/salinity/resistivity at the same time for maximum efficiency.

    • Powerful Data Management —Manual/automatic data logger with 2000 sets of GLP-compliant data storage, including electrode ID, user ID, sample ID, company name, and optional calibration password protection.

      Export data via USB to PC or a mini-printer (sold separately).

    • i-Guide On-Screen Tutorials — Press the “i” key at any time for step-by-step setup and calibration instructions displayed directly on the screen.

    • Apera TestBench Included — Integrated workstation with a flexible electrode holder, intelligent magnetic stirrer, and buffer organizers — dramatically streamlines calibration and measurement workflows.

    pH/mV (ORP) Measurement

    • LabSen® 211 pH Electrode — Features a low-impedance glass membrane and long-life reference system for ±0.003 pH accuracy. Supports 0–100°C ATC via the MP500 temperature probe. Compatible with TRIS buffers.
    • Flexible Calibration Options — 1 to 5 point auto. calibration recognizing standard buffers (1.68 / 4.00 / 7.00 / 10.01 / 12.45) or user-defined standards. Automatic electrode slope display and calibration self-diagnosis.

    • Broad Compatibility — Standard BNC pH connector & RCA temperature connector (NTC 30KΩ). Compatible with all Swiss LabSen electrodes for specialized samples.

    Conductivity/TDS/Salinity/Resistivity Measurement

    • 2401T-F Conductivity Electrode (Included) — Glass-body delivers high-accuracy measurements from 0 to 200 mS/cm at ±0.5% F.S accuracy.

    • Flexible Conductivity Calibration — 1 to 4 point auto. calibration with standard solutions (84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm) or user-defined standards.

    • Quick Parameter Switching — One-tap conversion among conductivity, TDS, salinity, and resistivity.

    • Multiple Salinity Modes — Select from general salinity, saltwater salinity, or NaCl salinity.

    • Broad Compatibility — Standard BNC conductivity connector; compatible with 2310T-F (up to 2000 mS/cm) and DJS-0.1-F for high-purity water. Uses RCA temperature connector (NTC 30KΩ).

    Parameter Settings Menu

    Menu Parameter Options Default
    pH pH Buffer Standard USA / NIST / User USA
    Resolution 0.001 / 0.01 / 0.1 0.01
    Calibration Info View / Print View
    Calibration Reminder Off / Hour / Day Off
    Stability Standard Low / Medium / High Medium
    Max/Min Reading Alarm Off / Max / Min Off
    Display Mode Digital / Dial Digital
    Electrode ID Custom Input ---
    Back to Factory Default No / Yes No
    Conductivity / TDS / Salinity Cell Constant 10 / 1.0 / 0.1 1.0
    Calibration Standard Standard / CH / User Standard
    Calibration Info Check / Print Check
    Calibration Reminder Off / Hour / Day Off
    Reference Temp. 15–30°C 25°C
    Temp. Compensation Coefficient 0.00–10.00% 2.00%
    TDS Factor 0.40–1.00 0.71
    Salinity Type Linear / NaCl / Saltwater (Seawater) Linear
    Electrode ID Custom Input ---
    Back to Factory Default No / Yes No
    Data Management Logging Destination Memory / Printer / PC Memory
    Logging Mode Manual / Auto Manual
    Printing Format Simple / Complete Simple
    Delete Data Yes / No No
    General Settings Sample ID Custom Input ---
    User ID Custom Input ---
    Company Name Custom Input ---
    Calibration Password Custom Input None
    Display Info Simple / Complete Simple
    Auto Hold On / Off Off
    Temperature Unit °C / °F °C
    Date Format YYYY-MM-DD / MM-DD-YYYY / DD-MM-YYYY YYYY-MM-DD
    Language English / German / Spanish / French / Italian / Chinese / Japanese English

    What's in the Kit?

    Item Quantity
    PC9500 pH/Conductivity Meter 1
    606 Test-Bench (with flexible electrode holder) 1
    LabSen 211 Glass pH Combination Electrode 1
    MP500 Temperature Electrode 1
    2401T-F Conductivity Electrode (ATC, K=1.0) 1
    pH Standard Buffers (4.00 / 7.00 / 10.01 pH, 50mL each) 3
    Conductivity Calibration Solutions (84 µS / 1413 µS / 12.88 mS, 50mL each) 3
    Stirrer Power Cable 1
    USB Cable 1
    PC-Link 9500 Flash Drive 1
    9V Adapter 1
    Calibration Vials 6
    L200 Stir Beads 6
    User Manual 1

    pH

    Range

    -2.000 to 20.000 pH

    Resolution

    0.1/0.01 /0.001pH

    Accuracy

    ±.002 pH ± 1 digit

    Temp. Compensation Range

    0 to 100°C (auto. or manual)

    Calibration Points

    1 to 5 points

    Buffer Series Options

    USA, NIST, CH, and User-Define

    mV

    Range

    ±2000.0 mV

    Resolution

    0.1 mV

    Accuracy

    ±0.03% F.S ± 1 digit

    Conductivity

    Range

    0~2000 mS/cm, divided into five ranges, automatically switch measuring range.

    (0 to 19.99) μS/cm;

    (20.0 to 199.9) μS/cm; 

    (200 to 1999) μS/cm;

    (2.00 to 19.99) mS/cm;

    (20.0 to 199.9) mS/cm

    (200.0 to 2000) mS/cm

    Resolution

    0.01/0.1/1μS/cm; 0.01/0.1/1 mS/cm

    Accuracy

    ±0.5% F.S

    Temp. Compensation Range

    0 to 50°C (auto. or manual)

    Cell Constant

    0.1/1/10 cm-1

    Reference Temp.

    15 to 30°C (adjustable)

    Temp. Compensation Coefficient

    0.00 to 10.00% (adjustable)

    Calibration Points

    1 to 4 points

    Standard Series Options

    Standard, CH, User-Define

    TDS

    Range

    0.00 mg/L to 1000 g/L

    Resolution

    0.01/0.1/1mg/L; 0.01/0.1/1 g/L

    Accuracy

    ±0.5% F.S

    Temp. Compensation Range

    0 to 50°C (auto. or manual)

    TDS Factor

    0.40 to 1.00 (adjustable)

    Salinity

    Range

    0.00 to 100 ppt

    Resolution

    0.01/0.1 ppt

    Accuracy

    ±0.5% F.S

    Temp. Compensation Range

    0 to 50° (auto. or manual)

    Salinity Type

    Linear / NaCl / Saltwater

    Resistivity

    Range

    0.00 Ω·m to 100MΩ·m

    Resolution

    0.1/1 Ω·m; 0.01/0.1/1KΩ·m; 0.1 MΩ·m

    Accuracy

    ±0.5% F.S

    Temp. Compensation Range

    0 to 50°C (auto. or manual)

    Temperature

    Range

    -10.0 to 110.0°; 14.0 to 230°

    Resolution

    0.1; 0.1/1

    Accuracy

    ±0.5°C

    pH

    Range

    -2.000 to 20.000 pH

    Resolution

    0.1/0.01 /0.001pH

    Accuracy

    ±.002 pH ± 1 digit

    Temp. Compensation Range

    0 to 100°C (auto. or manual)

    Calibration Points

    1 to 5 points

    Buffer Series Options

    USA, NIST, CH, and User-Define

    mV

    Range

    ±2000.0 mV

    Resolution

    0.1 mV

    Accuracy

    ±0.03% F.S ± 1 digit

    Conductivity

    Range

    0~2000 mS/cm, divided into five ranges, automatically switch measuring range.

    (0 to 19.99) μS/cm;

    (20.0 to 199.9) μS/cm; 

    (200 to 1999) μS/cm;

    (2.00 to 19.99) mS/cm;

    (20.0 to 199.9) mS/cm

    (200.0 to 2000) mS/cm

    Resolution

    0.01/0.1/1μS/cm; 0.01/0.1/1 mS/cm

    Accuracy

    ±0.5% F.S

    Temp. Compensation Range

    0 to 50°C (auto. or manual)

    Cell Constant

    0.1/1/10 cm-1

    Reference Temp.

    15 to 30°C (adjustable)

    Temp. Compensation Coefficient

    0.00 to 10.00% (adjustable)

    Calibration Points

    1 to 4 points

    Standard Series Options

    Standard, CH, User-Define

    TDS

    Range

    0.00 mg/L to 1000 g/L

    Resolution

    0.01/0.1/1mg/L; 0.01/0.1/1 g/L

    Accuracy

    ±0.5% F.S

    Temp. Compensation Range

    0 to 50°C (auto. or manual)

    TDS Factor

    0.40 to 1.00 (adjustable)

    Salinity

    Range

    0.00 to 100 ppt

    Resolution

    0.01/0.1 ppt

    Accuracy

    ±0.5% F.S

    Temp. Compensation Range

    0 to 50° (auto. or manual)

    Salinity Type

    Linear / NaCl / Saltwater

    Resistivity

    Range

    0.00 Ω·m to 100MΩ·m

    Resolution

    0.1/1 Ω·m; 0.01/0.1/1KΩ·m; 0.1 MΩ·m

    Accuracy

    ±0.5% F.S

    Temp. Compensation Range

    0 to 50°C (auto. or manual)

    Temperature

    Range

    -10.0 to 110.0°; 14.0 to 230°

    Resolution

    0.1; 0.1/1

    Accuracy

    ±0.5°C