SX751 8-in-1 Portable pH/DO/ORP/Conductivity/TDS/Salinity/Resistivity/Temperature Meter Kit
- Description
- Specs
- Videos
- Citations
- Parts
- Documents
- Warranty
Apera SX751 is designed for lab-grade measurement of up to 8 water quality parameters in the field, including pH, ORP (redox), DO (dissolved oxygen), conductivity, TDS, salinity, and resistivity. It is suitable for general water solutions’ applications such as water treatment, groundwater, surface water, hydroponics, environmental monitoring, aquaculture, aquarium, beverage making, etc.
Basic Features
- Intelligent functions –– auto. calibration, auto. temperature compensation, self-diagnosis, data logging, auto. power off, and more.
- Digital filter technology –– enhance the meter’s response time and measurement accuracy
- Automatic electrode recognition –– the meter automatically switches to the right parameter mode according to the connected electrode
- Data logging –– 400 sets of data storage and recall
- Built tough –– IP57 water-resistant structure, ideal for use in harsh environment
pH Features
- Built with lithium glass membrane and fiber ceramic junction, the 201T-S pH/temp. electrode provides the foundation for quick response and accurate pH readings.
- 1 to 3 points of quick auto. calibration, recognizing up to 13 kinds of pH buffers.
- The self-diagnosis function helps you understand common problems and how to fix them.
- With the 8-pin to BNC converter (sold separately), a variety of LabSen pH electrodes can be connected to meet the testing needs of specialized applications.
Conductivity Features
- Built with Apera’s proprietary platinum black, the 2301T-S conductivity/temp. electrode ensures high accuracy (±1% F.S) in a wide-range (0 to 200,000 µS/cm)
- Simple 1-point automatic calibration, recognizing up to 8 kinds of conductivity standards
- Easy switch to TDS, salinity, and resistivity
- 0 to 50˚C Automatic temperature compensation
- Non-linear temperature compensation will be triggered if the sample’s conductivity is <10µS/cm, significantly increasing the reading accuracy for pure water.
DO Features
- Equipped with Apera's DO500 polarographic DO electrode, featuring quick response and integrated temperature and salinity sensors.
- Replaceable DO membrane cap (3 replacement membrane caps and an inner solution refill are included in the kit).
- Regular electrode polarization only takes 5 minutes. Measurement reaches 90% response within 30 seconds.
- Automatic compensation for temperature and salinity; manual compensation for barometric pressure
ORP Features
- Equipped with 301Pt-S Platinum ORP electrode featured with stable potential and fast response
- No need for ORP calibration
- The platinum sensor is easy to clean and maintain
Comes as a complete test kit in a rugged carrying case for convenient field test

pH
Measurement range
(-2.00 to 19.99) pH
Resolution
0.1/0.01 pH
Accuracy
±0.01pH±1 digit
Input current
≤2×10-12 A
Input impedance
≥1×1012 Ω
Temp. compensation range
(0 to 100) ˚C (automatic)
ORP
Measurement range (mV/ORP/EH)
-1999 mV to 1999mV
Resolution
1mV
Accuracy
±15mV
Conductivity
Measurement range
Conductivity:
(0.00 to 19.99) μS/cm (20.0 to 199.9) μS/cm
(200 to 1999) μS/cm (2.00 to 19.99) mS/cm
(20.0 to 199.9) mS/cm
TDS: (0 to 100) g/L; Salinity : (0 to 100) ppt
Resistivity: (0 to 100) MΩ·cm
Resolution
0.01/0.1/1μS/cm; 0.01/0.1 mS/cm
Accuracy
±1.0% F.S
Temp. compensation range
(0 to 50) ˚C (automatic)
Electrode constant
0.1 / 1 / 10 cm-1
Reference temperature
25˚C, 20˚C, and 18˚C
Dissolved Oxygen
Measurement range
(0 to 19.99) mg/L (ppm); (0 to 200.0) %
Resolution
0.1/0.01 mg/L (ppm) 1/0.1%
Accuracy
±0.30 mg/L (ppm)
Response time
≤30 seconds (25˚C, 90% response)
Temp. compensation range
(0 to 45) ˚C (automatic)
Salinity compensation range
(0 to 45) ppt (automatic)
Barometric pressure compensation range
(66 to 200) kPa (manual)
Automatic calibration
One or two points at 100% (water-saturated air) and
0%
Electrode type
Polarographic
Other Technical Parameters
Data storage
400 sets
Data content
Serial number, measurement value, measurement unit, and temperature
Power Supply
Two AA alkaline batteries (1.5V x2)
Dimensions and weight
Meter: (65×120×31) mm/180g
Complete Kit: (255 x 210x 50) mm/1760g
Quality and safety certification
CE, ISO 9001:2015
Working Condition
Working temperature
5 to 35˚C
Working humidity
≤85%
IP rating
IP57 water-resistant
Videos - Citations
We warrant this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of THREE YEARS for the instrument and SIX MONTHS for the probe from the delivery.
This limited warranty does NOT cover any issues due to:
- Accidental damage
- Improper use
- Normal wear and tear
- Transportation
- Storage
- Failure to follow the product instructions
- Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
- Unauthorized repair
- External causes such as accidents, abuse, or other actions or events beyond our reasonable control.
- Description
- Specs
- Videos
- Citations
- Documents
- Parts
- Warranty
Apera SX751 is designed for lab-grade measurement of up to 8 water quality parameters in the field, including pH, ORP (redox), DO (dissolved oxygen), conductivity, TDS, salinity, and resistivity. It is suitable for general water solutions’ applications such as water treatment, groundwater, surface water, hydroponics, environmental monitoring, aquaculture, aquarium, beverage making, etc.
Basic Features
- Intelligent functions –– auto. calibration, auto. temperature compensation, self-diagnosis, data logging, auto. power off, and more.
- Digital filter technology –– enhance the meter’s response time and measurement accuracy
- Automatic electrode recognition –– the meter automatically switches to the right parameter mode according to the connected electrode
- Data logging –– 400 sets of data storage and recall
- Built tough –– IP57 water-resistant structure, ideal for use in harsh environment
pH Features
- Built with lithium glass membrane and fiber ceramic junction, the 201T-S pH/temp. electrode provides the foundation for quick response and accurate pH readings.
- 1 to 3 points of quick auto. calibration, recognizing up to 13 kinds of pH buffers.
- The self-diagnosis function helps you understand common problems and how to fix them.
- With the 8-pin to BNC converter (sold separately), a variety of LabSen pH electrodes can be connected to meet the testing needs of specialized applications.
Conductivity Features
- Built with Apera’s proprietary platinum black, the 2301T-S conductivity/temp. electrode ensures high accuracy (±1% F.S) in a wide-range (0 to 200,000 µS/cm)
- Simple 1-point automatic calibration, recognizing up to 8 kinds of conductivity standards
- Easy switch to TDS, salinity, and resistivity
- 0 to 50˚C Automatic temperature compensation
- Non-linear temperature compensation will be triggered if the sample’s conductivity is <10µS/cm, significantly increasing the reading accuracy for pure water.
DO Features
- Equipped with Apera's DO500 polarographic DO electrode, featuring quick response and integrated temperature and salinity sensors.
- Replaceable DO membrane cap (3 replacement membrane caps and an inner solution refill are included in the kit).
- Regular electrode polarization only takes 5 minutes. Measurement reaches 90% response within 30 seconds.
- Automatic compensation for temperature and salinity; manual compensation for barometric pressure
ORP Features
- Equipped with 301Pt-S Platinum ORP electrode featured with stable potential and fast response
- No need for ORP calibration
- The platinum sensor is easy to clean and maintain
Comes as a complete test kit in a rugged carrying case for convenient field test

pH
Measurement range
(-2.00 to 19.99) pH
Resolution
0.1/0.01 pH
Accuracy
±0.01pH±1 digit
Input current
≤2×10-12 A
Input impedance
≥1×1012 Ω
Temp. compensation range
(0 to 100) ˚C (automatic)
ORP
Measurement range (mV/ORP/EH)
-1999 mV to 1999mV
Resolution
1mV
Accuracy
±15mV
Conductivity
Measurement range
Conductivity:
(0.00 to 19.99) μS/cm (20.0 to 199.9) μS/cm
(200 to 1999) μS/cm (2.00 to 19.99) mS/cm
(20.0 to 199.9) mS/cm
TDS: (0 to 100) g/L; Salinity : (0 to 100) ppt
Resistivity: (0 to 100) MΩ·cm
Resolution
0.01/0.1/1μS/cm; 0.01/0.1 mS/cm
Accuracy
±1.0% F.S
Temp. compensation range
(0 to 50) ˚C (automatic)
Electrode constant
0.1 / 1 / 10 cm-1
Reference temperature
25˚C, 20˚C, and 18˚C
Dissolved Oxygen
Measurement range
(0 to 19.99) mg/L (ppm); (0 to 200.0) %
Resolution
0.1/0.01 mg/L (ppm) 1/0.1%
Accuracy
±0.30 mg/L (ppm)
Response time
≤30 seconds (25˚C, 90% response)
Temp. compensation range
(0 to 45) ˚C (automatic)
Salinity compensation range
(0 to 45) ppt (automatic)
Barometric pressure compensation range
(66 to 200) kPa (manual)
Automatic calibration
One or two points at 100% (water-saturated air) and
0%
Electrode type
Polarographic
Other Technical Parameters
Data storage
400 sets
Data content
Serial number, measurement value, measurement unit, and temperature
Power Supply
Two AA alkaline batteries (1.5V x2)
Dimensions and weight
Meter: (65×120×31) mm/180g
Complete Kit: (255 x 210x 50) mm/1760g
Quality and safety certification
CE, ISO 9001:2015
Working Condition
Working temperature
5 to 35˚C
Working humidity
≤85%
IP rating
IP57 water-resistant
pH
Measurement range
(-2.00 to 19.99) pH
Resolution
0.1/0.01 pH
Accuracy
±0.01pH±1 digit
Input current
≤2×10-12 A
Input impedance
≥1×1012 Ω
Temp. compensation range
(0 to 100) ˚C (automatic)
ORP
Measurement range (mV/ORP/EH)
-1999 mV to 1999mV
Resolution
1mV
Accuracy
±15mV
Conductivity
Measurement range
Conductivity:
(0.00 to 19.99) μS/cm (20.0 to 199.9) μS/cm
(200 to 1999) μS/cm (2.00 to 19.99) mS/cm
(20.0 to 199.9) mS/cm
TDS: (0 to 100) g/L; Salinity : (0 to 100) ppt
Resistivity: (0 to 100) MΩ·cm
Resolution
0.01/0.1/1μS/cm; 0.01/0.1 mS/cm
Accuracy
±1.0% F.S
Temp. compensation range
(0 to 50) ˚C (automatic)
Electrode constant
0.1 / 1 / 10 cm-1
Reference temperature
25˚C, 20˚C, and 18˚C
Dissolved Oxygen
Measurement range
(0 to 19.99) mg/L (ppm); (0 to 200.0) %
Resolution
0.1/0.01 mg/L (ppm) 1/0.1%
Accuracy
±0.30 mg/L (ppm)
Response time
≤30 seconds (25˚C, 90% response)
Temp. compensation range
(0 to 45) ˚C (automatic)
Salinity compensation range
(0 to 45) ppt (automatic)
Barometric pressure compensation range
(66 to 200) kPa (manual)
Automatic calibration
One or two points at 100% (water-saturated air) and
0%
Electrode type
Polarographic
Other Technical Parameters
Data storage
400 sets
Data content
Serial number, measurement value, measurement unit, and temperature
Power Supply
Two AA alkaline batteries (1.5V x2)
Dimensions and weight
Meter: (65×120×31) mm/180g
Complete Kit: (255 x 210x 50) mm/1760g
Quality and safety certification
CE, ISO 9001:2015
Working Condition
Working temperature
5 to 35˚C
Working humidity
≤85%
IP rating
IP57 water-resistant
pH
Measurement range
(-2.00 to 19.99) pH
Resolution
0.1/0.01 pH
Accuracy
±0.01pH±1 digit
Input current
≤2×10-12 A
Input impedance
≥1×1012 Ω
Temp. compensation range
(0 to 100) ˚C (automatic)
ORP
Measurement range (mV/ORP/EH)
-1999 mV to 1999mV
Resolution
1mV
Accuracy
±15mV
Conductivity
Measurement range
Conductivity:
(0.00 to 19.99) μS/cm (20.0 to 199.9) μS/cm
(200 to 1999) μS/cm (2.00 to 19.99) mS/cm
(20.0 to 199.9) mS/cm
TDS: (0 to 100) g/L; Salinity : (0 to 100) ppt
Resistivity: (0 to 100) MΩ·cm
Resolution
0.01/0.1/1μS/cm; 0.01/0.1 mS/cm
Accuracy
±1.0% F.S
Temp. compensation range
(0 to 50) ˚C (automatic)
Electrode constant
0.1 / 1 / 10 cm-1
Reference temperature
25˚C, 20˚C, and 18˚C
Dissolved Oxygen
Measurement range
(0 to 19.99) mg/L (ppm); (0 to 200.0) %
Resolution
0.1/0.01 mg/L (ppm) 1/0.1%
Accuracy
±0.30 mg/L (ppm)
Response time
≤30 seconds (25˚C, 90% response)
Temp. compensation range
(0 to 45) ˚C (automatic)
Salinity compensation range
(0 to 45) ppt (automatic)
Barometric pressure compensation range
(66 to 200) kPa (manual)
Automatic calibration
One or two points at 100% (water-saturated air) and
0%
Electrode type
Polarographic
Other Technical Parameters
Data storage
400 sets
Data content
Serial number, measurement value, measurement unit, and temperature
Power Supply
Two AA alkaline batteries (1.5V x2)
Dimensions and weight
Meter: (65×120×31) mm/180g
Complete Kit: (255 x 210x 50) mm/1760g
Quality and safety certification
CE, ISO 9001:2015
Working Condition
Working temperature
5 to 35˚C
Working humidity
≤85%
IP rating
IP57 water-resistant
Compatibility
We warrant this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of THREE YEARS for the instrument and SIX MONTHS for the probe from the delivery.
This limited warranty does NOT cover any issues due to:
- Accidental damage
- Improper use
- Normal wear and tear
- Transportation
- Storage
- Failure to follow the product instructions
- Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
- Unauthorized repair
- External causes such as accidents, abuse, or other actions or events beyond our reasonable control.